Metadata-Version: 2.1
Name: nibe-mqtt
Version: 0.3.1
Summary: Nibe heatpump MQTT integration
Home-page: https://github.com/yozik04/nibe-mqtt
Author: Jevgeni Kiski
Author-email: yozik04@gmail.com
License: LGPL 3
Project-URL: Bug Tracker, https://github.com/yozik04/nibe-mqtt/issues
Keywords: nibe modbus library nibegw mqtt
Classifier: Development Status :: 1 - Planning
Classifier: Intended Audience :: Developers
Classifier: License :: OSI Approved :: GNU Lesser General Public License v3 (LGPLv3)
Classifier: Operating System :: OS Independent
Classifier: Programming Language :: Python
Classifier: Programming Language :: Python :: 3 :: Only
Classifier: Programming Language :: Python :: 3.9
Classifier: Programming Language :: Python :: 3.10
Requires-Python: >=3.9
Description-Content-Type: text/markdown
License-File: LICENSE

# Nibe MQTT integration
MQTT integration for controlling Nibe heatpumps. Supports HomeAssistant MQTT Autodiscovery.

Uses [nibe](https://github.com/yozik04/nibe) library which supports connections:
  - RS485 communication via NibeGW developed by Pauli Anttila for [Openhab's integration](https://www.openhab.org/addons/bindings/nibeheatpump/)
  - TCP/Serial Modbus (experimental)

#### Supported heatpump models
 - F1145
 - F1155
 - F1245
 - F1255
 - F1345
 - F1355
 - F370
 - F470
 - F730
 - F750
 - SMO20
 - SMO40
 - VVM225
 - VVM310
 - VVM320
 - VVM325
 - VVM500

Additionally, supports some S series through TCP Modbus (experimental)

## Installation
### PyPi
It is possible to install directly from PyPi
```bash
pip3 install nibe-mqtt
```

Then you will be able to run the service with command
```bash
nibe-mqtt -c config.yaml
```

### Docker
See [Docker Hub](https://hub.docker.com/repository/docker/yozik04/nibe-mqtt) for available versions (tags)

Run with:
```bash
docker run -ti --pull=always --rm -p 9999:9999/udp -v "/Users/myuser/Desktop/config.yaml:/config/nibe-mqtt/config.yaml:ro" yozik04/nibe-mqtt:latest
```

## Basic configuration

### With NibeGW:
```yaml
mqtt:
  host: 192.168.1.2
  protocol: 5
  username: user
  password: pass
nibe:
  model: F1255
  word_swap: true
  nibegw:
    ip: 192.168.1.3
  poll:
    coils:
      - bt50-room-temp-s1-40033
```

For all configuration options lookup in config.py

### With Modbus:
```yaml
mqtt:
  host: 192.168.1.2
  protocol: 5
  username: user
  password: pass
nibe:
  model: F1255
  word_swap: true
  modbus:
    url: tcp://192.168.1.3:502
    slave_id: 1
  poll:
    coils:
      - bt50-room-temp-s1-40033
```

For all configuration options lookup in config.py

## Supported coils
See the list of available parameters [here](https://github.com/yozik04/nibe/tree/master/nibe/data)

## Word swap
You need to specify `word_swap` setting to let this library understand how to decode 32-bit integers (mostly counters)

There is a setting called `word swap` in Nibe service menu 5.3.11 (`modbus settings`).

You need to set `word_swap` setting in yaml to match the setting in the service menu.

Failing to do so will start throwing errors about values out of bounds.

## Disclaimer
Nibe is registered mark of NIBE Energy Systems.

The code was developed as a way of integrating personally owned Nibe heatpump, and it cannot be used for other purposes. It is not affiliated with any company, and it doesn't have a commercial intent.

The code is provided AS IS and the developers will not be held responsible for failures in the heatpump operation or any other malfunction.