PWG-IMAGING-COUNTER-MIB DEFINITIONS ::= BEGIN
--  PWG Imaging Counter MIB
--  counter-mib-20041127.txt
--  version 0.40 - 27 November 2004

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, enterprises
        FROM SNMPv2-SMI                 -- RFC 2578
    TEXTUAL-CONVENTION, DisplayString
        FROM SNMPv2-TC                  -- RFC 2579
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF                -- RFC 2580
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB;        -- RFC 3411

icMIB MODULE-IDENTITY
    LAST-UPDATED    "0411270000Z" -- 27 November 2004
    ORGANIZATION    "Printer Working Group, a Program of IEEE/ISTO"
    CONTACT-INFO
        "Web-based Imaging Management Services (WIMS) Project

        Web:    http://www.pwg.org
        FTP:    ftp://ftp.pwg.org/pub/pwg/wims
        Email:  wims@pwg.org (subscribers only - see Web page above)

        Editor: Ira McDonald
        Postal: High North Inc
                PO Box 221 - E21761 Ridge Ave
                Grand Marais, MI  49839
                USA
        Tel:    +1 906-494-2434
        Email:  imcdonald@sharplabs.com"
    DESCRIPTION
        "The MIB module for passive monitoring of activity counters for
        managed services and/or managed subunits on an Imaging System.

        Copyright (C) IEEE/ISTO PWG (2004)."

    -- revision history
    REVISION        "0411270000Z" -- 27 November 2004 (v0.40)
    DESCRIPTION     "Third revision of the Imaging Counter MIB.
                    - major rewrite, including all INDEX clauses,
                      to align with PWG Counter spec and schema,
                      per request of Pete Zehler.
                    - added 'IcServiceTypeTC' and 'IcSubunitTypeTC'
                      textual conventions for use in 'icServiceTable'
                      and 'icSubunitTable' (for direct lookup of keys).
                    - added 'IcWorkTypeTC' (for direct lookup of 'job',
                      'datastream', 'auxiliary', etc. work counters),
                      to align with PWG Counter spec and schema.
                    - added 'IcCycleTypeTC' (for direct lookup of
                      'life', 'power', and 'reset' scope work counters),
                      to align with PWG Counter spec and schema.
                    - added 'icGeneral' scalar objects group, to support
                      (missing) language tag for 'ic...Info' objects
                      and counts of services, subunits, and media used
                      types (for efficient SNMP access without errors).
                    - added 'icKeyTable', to support lookup of all
                      service and subunit keys configured.
                    - added 'icServiceTable' and 'icSubunitTable',
                      to support direct lookup of any specific service
                      or subunit (but simplify indexing of work tables).
                    - renamed 'icBasicTable' to 'icMonitorTable' and
                      added 'icMonitorMemoryAlloc...' counters,
                      to align with PWG Counter spec and schema.
                    - deleted 'icJobSetTable' and moved all of the job
                      completion counters to 'icMonitorTable',
                      to align with PWG Counter spec and schema.
                    - added 'icTwoSidedTable' for duplex impressions,
                      to align with PWG Counter spec and schema.
                    - renamed 'icTrafficInputChannelKOctets' to
                      'icTrafficJobInputKOctets' (for clarity) and
                      added symmetric 'icTrafficJobOutputKOctets'
                      (for 'faxIn/Out' and 'netFaxIn/Out'),
                      per October review at PWG Lexington face-to-face.
                    - added 'icTrafficInputMessages' and symmetric
                      'icTrafficOutputMessages' (for 'emailIn/Out'),
                      per October review at PWG Lexington face-to-face."

    REVISION        "0404280000Z" -- 28 April 2004 (v0.30)
    DESCRIPTION     "Second revision of the Imaging Counter MIB.
                    - revised all INDEX clauses to:  '...ElementClass',
                      '...ServiceType', and '...KeyIndex' (for
                      efficient access to a specific element instance),
                      per request of Pete Zehler.
                    - added 'icJobSetTable' for the job counters removed
                      from 'icBasicTable' (only applicable to system,
                      service, or device managed elements).
                    - renamed 'icJobSetFinishedJobs' to
                      'icJobSetCompletedFinisherJobs' for clarity,
                      per request of Pete Zehler.
                    - renamed 'icTrafficChannelDataKOctets' to
                      'icTrafficInputChannelKOctets' and revised
                      description, per request of Pete Zehler.
                    - renamed 'icMediaTable' to 'icMediaUsedTable' for
                      clarity, per WIMS discussions.
                    - revised indices of 'icMediaUsedTable' to be
                      'icMediaUsedSizeName' and 'icMediaUsedIndex',
                      per request of Pete Zehler.
                    - revised 'icMediaUsedInfo' to make it mandatory to
                      distinguish between same media size instances,
                      per request of Pete Zehler."

    REVISION        "0404050000Z" -- 5 April 2004 (v0.20)
    DESCRIPTION     "First revision of the Imaging Counter MIB.
                    - decomposed former 'icTable' into six tables
                      (3 mandatory and 3 conditionally mandatory).
                    - added 'IcPersistenceTC' to extend original
                      'StorageType' from RFC 2579 like Resource object.
                    - added 'icBasic[Aborted|Canceled|Completed]Jobs'
                      and 'icBasicFinisherJobs', to complement Job Mon
                      MIB (RFC 2707), per WIMS discussions.
                    - added 'icMediaTable' (optional) for media actually
                      consumed, per WIMS discussions."

    REVISION        "0403120000Z" -- 12 March 2004 (v0.10)
    DESCRIPTION     "Initial version of the Imaging Counter MIB."
    ::= { enterprises pwg(2699)  mibs(1)  imagingCounterMIB(3) }

--  PWG Secretary - MIB module number should be assigned/registered


icMIBObjects            OBJECT IDENTIFIER ::= { icMIB 1 }

icMIBNotifications      OBJECT IDENTIFIER ::= { icMIB 2 }

icMIBConformance        OBJECT IDENTIFIER ::= { icMIB 3 }
icMIBObjectGroups       OBJECT IDENTIFIER ::= { icMIBConformance 2 }


--
-- Textual Conventions
--

IcCycleTypeTC ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    REFERENCE
        "See:   'prtMarkerLifeCount' and 'prtMarkerPowerOnCount'
                in Printer MIB (RFC 1759/3805)."
    SYNTAX      INTEGER {
        other(1),                       -- non-standard type
        unknown(2),                     -- unknown type
        life(3),                        -- since last install
                                        -- see 'prtMarkerLifeCount'
        power(4),                       -- since last power-on
                                        -- see 'prtMarkerPowerOnCount'
        reset(5)                        -- since last counter reset
                                        -- by administrative operation
    }

IcServiceTypeTC ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The type of this managed service on this Imaging System."
    REFERENCE
        "See:   'JmJobServiceTypesTC' and 'jobServiceTypes'
                in Job Mon MIB (RFC 2707)."
    SYNTAX      INTEGER {
        other(1),                       -- non-standard type
        unknown(2),                     -- unknown type
        system(3),                      -- Imaging System (totals)
        copy(4),                        -- copy (scan and print)
        emailIn(5),                     -- email (input messages)
        emailOut(6),                    -- email (output messages)
        faxIn(7),                       -- PSTN fax (input images)
        faxOut(8),                      -- PSTN fax (output images)
        networkFaxIn(9),                -- network fax (input images)
        networkFaxOut(10),              -- network fax (output images)
        print(11),                      -- print (output impressions)
        scan(12),                       -- scan (input images)
        scanToEmail(13),                -- scan to email (output images)
        scanToFile(14),                 -- scan to file (output images)
        transform(15)                   -- transform (convert format)
    }

IcSubunitTypeTC ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The type of this managed subunit on this Imaging System."
    REFERENCE
        "See:   Section 2.2 'Printer Sub-Units'
                in Printer MIB (RFC 1759/3805)."
    SYNTAX      INTEGER {
        other(1),                       -- non-standard type
        unknown(2),                     -- unknown type
        channel(3),                     -- input job source
        console(4),                     -- Imaging System local console
        cover(5),                       -- cover, door, or interlock
        finisher(6),                    -- hardcopy media finishing
        inputTray(7),                   -- input media source
        interface(8),                   -- local/network hardware port
        interpreter(9),                 -- rendering for hardcopy output
        marker(10),                     -- hardcopy impression target
        mediaPath(11),                  -- input tray to output bin
        outputBin(12),                  -- output media target
        scanner(13),                    -- softcopy image source
        transformer(14)                 -- document format conversion
    }

IcWorkTypeTC ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "The type of work for these counters."
    SYNTAX      INTEGER {
        other(1),                       -- non-standard type
        unknown(2),                     -- unknown type
        job(3),                         -- work totals
        datastream(4),                  -- work from user datastream
        auxiliary(5),                   -- hardcopy startup/banner/etc.
        waste(6),                       -- hardcopy waste
        maintenance(7)                  -- work during maintenance
    }


--
--  General Group (Mandatory)
--

icGeneral               OBJECT IDENTIFIER ::= { icMIBObjects 1 }

icGeneralNaturalLanguage OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..63))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The natural language tag (RFC 3066), specified in US-ASCII,
        for all text string objects defined in this MIB.

        Note:  If this object is empty, then the natural language for
        all text string objects defined in this MIB SHOULD default to
        'en-US' (US English)."
    REFERENCE
        "See:   'prtGeneralCurrentLocalization' in RFC 1759/3805."
    DEFVAL      { ''H }                 -- no natural language tag
    ::= { icGeneral 1 }

icGeneralTotalServiceRecords OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "records"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total managed services configured on this Imaging System,
        and therefore the number of entries in 'icServiceTable'."
    ::= { icGeneral 2 }

icGeneralTotalSubunitRecords OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "records"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total managed subunits configured on this Imaging System,
        and therefore the number of entries in 'icSubunitTable'."
    ::= { icGeneral 3 }

icGeneralTotalMediaUsedRecords OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "records"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total records of specific media used on this Imaging System,
        and therefore the number of entries in 'icMediaUsedTable'."
    ::= { icGeneral 4 }


--
--  Key Group (Mandatory)
--

icKey                   OBJECT IDENTIFIER ::= { icMIBObjects 2 }

icKeyTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcKeyEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of the local unique integer keys for managed services
        and/or managed subunits on this Imaging System."
    ::= { icKey 1 }

icKeyEntry OBJECT-TYPE
    SYNTAX      IcKeyEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A entry of one local unique integer key for a managed service
        or a managed subunit on this Imaging System."
    INDEX     { icKeyIndex }
    ::= { icKeyTable 1 }


IcKeyEntry ::= SEQUENCE {
        --  key index elements
        icKeyIndex                      Integer32,

        --  key description elements
        icKeyServiceType                IcServiceTypeTC,
        icKeyServiceIndex               Integer32,
        icKeySubunitType                IcSubunitTypeTC,
        icKeySubunitIndex               Integer32
    }


icKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System.

        Usage:  The value of this key can be used in 'icXxxKeyIndex'
        for lookup of counters on this Imaging System."
    ::= { icKeyEntry 1 }

icKeyServiceType OBJECT-TYPE
    SYNTAX      IcServiceTypeTC
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The type of this managed service on this Imaging System
        (e.g., print, copy, etc.)."
    DEFVAL      { unknown }             -- no service type
    ::= { icKeyEntry 2 }

icKeyServiceIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Local unique integer identifier of this managed service
        on this Imaging System, or zero if none."
    DEFVAL      { 0 }                   -- no service identifier
    ::= { icKeyEntry 3 }

icKeySubunitType OBJECT-TYPE
    SYNTAX      IcSubunitTypeTC
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The type of this managed subunit on this Imaging System
        (e.g., print, copy, etc.)."
    DEFVAL      { unknown }             -- no subunit type
    ::= { icKeyEntry 4 }

icKeySubunitIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Local unique integer identifier of this managed subunit
        on this Imaging System, or zero if none."
    DEFVAL      { 0 }                   -- no subunit identifier
    ::= { icKeyEntry 5 }


--
--  Service Group (Mandatory)
--

icService               OBJECT IDENTIFIER ::= { icMIBObjects 3 }

icServiceTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcServiceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of managed services on this Imaging System."
    ::= { icService 1 }

icServiceEntry OBJECT-TYPE
    SYNTAX      IcServiceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry for a managed service on this Imaging System."
    INDEX     { icServiceType,
                icServiceIndex }
    ::= { icServiceTable 1 }


IcServiceEntry ::= SEQUENCE {
        --  service index elements
        icServiceType                   IcServiceTypeTC,
        icServiceIndex                  Integer32,

        --  service description elements
        icServiceKey                    Integer32,
        icServiceInfo                   SnmpAdminString,
        icServiceJobSetIndex            Integer32
    }

icServiceType OBJECT-TYPE
    SYNTAX      IcServiceTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of this managed service on this Imaging System
        (e.g., print, copy, etc.)."
    ::= { icServiceEntry 1 }

icServiceIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local unique integer identifier of this managed service
        on this Imaging System."
    ::= { icServiceEntry 2 }

icServiceKey OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (for lookup of counters)
        on this Imaging System."
    --  DEFVAL intentionally omitted - valid service key is REQUIRED
    ::= { icServiceEntry 3 }

icServiceInfo OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE(0..255))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The description of this managed service on this Imaging System,
        for use with remote network management scripts and GUIs.

        For example:    'Print service supporting IPP and PSI'."
    DEFVAL      { ''H }                 -- no service description
    ::= { icServiceEntry 4 }

icServiceJobSetIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..32767)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of 'jmGeneralJobSetIndex' in Job Mon MIB (RFC 2707)
        for this managed service, if the Job Mon MIB is implemented and
        this managed service is represented there, or zero if none."
    DEFVAL      { 0 }                   -- no service job set (queue)
    ::= { icServiceEntry 5 }


--
--  Subunit Group (Conditionally Mandatory)
--

icSubunit               OBJECT IDENTIFIER ::= { icMIBObjects 4 }

icSubunitTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcSubunitEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of managed subunits on this Imaging System."
    REFERENCE
        "See:   'prtGeneralTable' in Printer MIB (RFC 1759/3805)."
    ::= { icSubunit 1 }

icSubunitEntry OBJECT-TYPE
    SYNTAX      IcSubunitEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry for a managed subunit on this Imaging System."
    INDEX     { icSubunitType,
                icSubunitIndex }
    ::= { icSubunitTable 1 }


IcSubunitEntry ::= SEQUENCE {
        --  subunit index elements
        icSubunitType                   IcSubunitTypeTC,
        icSubunitIndex                  Integer32,

        --  subunit description elements
        icSubunitKey                    Integer32,
        icSubunitInfo                   SnmpAdminString
    }

icSubunitType OBJECT-TYPE
    SYNTAX      IcSubunitTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of this managed subunit on this Imaging System
        (e.g., channel, marker, etc.)."
    ::= { icSubunitEntry 1 }

icSubunitIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local unique integer identifier of this managed subunit
        on this Imaging System."
    ::= { icSubunitEntry 2 }

icSubunitKey OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Local key of this managed subunit (for lookup of counters)
        on this Imaging System."
    --  DEFVAL intentionally omitted - valid subunit key is REQUIRED
    ::= { icSubunitEntry 3 }

icSubunitInfo OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE(0..255))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The description of this managed subunit on this Imaging System,
        for use with remote network management scripts and GUIs.

        For example:    'Marker subunit supporting simplex and duplex'."
    DEFVAL      { ''H }                 -- no subunit description
    ::= { icSubunitEntry 4 }


--
--  Time Group (Mandatory)
--

icTime                  OBJECT IDENTIFIER ::= { icMIBObjects 5 }

icTimeTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcTimeEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of availability counters for managed services
        and/or managed subunits on this Imaging System."
    REFERENCE
        "See:   'icServiceTable' and 'icSubunitTable' in this MIB."
    ::= { icTime 1 }

icTimeEntry OBJECT-TYPE
    SYNTAX      IcTimeEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry of availability counters for a managed service
        or a managed subunit on this Imaging System."
    INDEX     { icTimeKeyIndex,
                icTimeCycleType }
    ::= { icTimeTable 1 }


IcTimeEntry ::= SEQUENCE {
        --  time index elements
        icTimeKeyIndex                  Integer32,
        icTimeCycleType                 IcCycleTypeTC,

        --  time counter elements
        icTimeTotalSeconds              Counter32,
        icTimeDownSeconds               Counter32,
        icTimeMaintenanceSeconds        Counter32,
        icTimeProcessingSeconds         Counter32
    }

icTimeKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System."
    ::= { icTimeEntry 1 }

icTimeCycleType OBJECT-TYPE
    SYNTAX      IcCycleTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    ::= { icTimeEntry 2 }

icTimeTotalSeconds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total time in seconds that this managed service or managed
        subunit has executed."
    ::= { icTimeEntry 3 }

icTimeDownSeconds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time in seconds that this managed service or managed subunit
        has been down with an error that requires intervention or
        prevents normal operation (i.e., unavailable to process jobs)."
    ::= { icTimeEntry 4 }

icTimeMaintenanceSeconds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time in seconds that this managed service or managed subunit
        has spent in maintenance mode (testing, field service, etc.)."
    ::= { icTimeEntry 5 }

icTimeProcessingSeconds OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time in seconds that this managed service or managed subunit
        has spent in processing jobs."
    ::= { icTimeEntry 6 }


--
--  Monitor Group (Mandatory)
--

icMonitor               OBJECT IDENTIFIER ::= { icMIBObjects 6 }

icMonitorTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcMonitorEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of monitoring counters for managed services
        and/or managed subunits on this Imaging System."
    REFERENCE
        "See:   'icServiceTable' and 'icSubunitTable' in this MIB."
    ::= { icMonitor 1 }

icMonitorEntry OBJECT-TYPE
    SYNTAX      IcMonitorEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry of monitoring counters for a managed service
        or a managed subunit on this Imaging System."
    INDEX     { icMonitorKeyIndex,
                icMonitorCycleType }
    ::= { icMonitorTable 1 }


IcMonitorEntry ::= SEQUENCE {
        --  monitor index elements
        icMonitorKeyIndex               Integer32,
        icMonitorCycleType              IcCycleTypeTC,

        --  monitor counter elements
        icMonitorConfigChanges          Counter32,
        icMonitorTotalAlerts            Counter32,
        icMonitorCriticalAlerts         Counter32,
        icMonitorAbortedJobs            Counter32,
        icMonitorCanceledJobs           Counter32,
        icMonitorCompletedJobs          Counter32,
        icMonitorCompletedFinisherJobs  Counter32,
        icMonitorMemoryAllocErrors      Counter32,
        icMonitorMemoryAllocWarnings    Counter32,
        icMonitorStorageAllocErrors     Counter32,
        icMonitorStorageAllocWarnings   Counter32
    }

icMonitorKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System."
    ::= { icMonitorEntry 1 }

icMonitorCycleType OBJECT-TYPE
    SYNTAX      IcCycleTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    ::= { icMonitorEntry 2 }

icMonitorConfigChanges OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total configuration changes that have occurred on this managed
        service or managed subunit (e.g., changes to attributes)."
    REFERENCE
        "See:   'prtGeneralConfigChanges' in Printer MIB v1 (RFC 1759)
                and Printer MIB v2 (RFC 3805)."
    ::= { icMonitorEntry 3 }

icMonitorTotalAlerts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total alerts that have occurred on this managed service
        or managed subunit."
    REFERENCE
        "See:   'prtAlertAllEvents' in Printer MIB v2."
    ::= { icMonitorEntry 4 }

icMonitorCriticalAlerts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Critical alerts that have occurred on this managed service
        or managed subunit."
    REFERENCE
        "See:   'prtAlertCriticalEvents' in Printer MIB v2."
    ::= { icMonitorEntry 5 }

icMonitorAbortedJobs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "jobs"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total jobs that have been aborted (by the system software)
        on this managed service or managed subunit."
    REFERENCE
        "See:   'jmJobState' and 'JmJobStateTC' in Job MIB (RFC 2707)."
    ::= { icMonitorEntry 6 }

icMonitorCanceledJobs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "jobs"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total jobs that have been canceled (by an authorized user)
        on this managed service or managed subunit."
    REFERENCE
        "See:   'jmJobState' and 'JmJobStateTC' in Job MIB (RFC 2707)."
    ::= { icMonitorEntry 7 }

icMonitorCompletedJobs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "jobs"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total jobs that have been completed (successfully or with
        warnings/errors) on this managed service or managed subunit."
    REFERENCE
        "See:   'jmJobState' and 'JmJobStateTC' in Job MIB (RFC 2707)."
    ::= { icMonitorEntry 8 }

icMonitorCompletedFinisherJobs OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "jobs"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total jobs that have been completed (successfully or with
        warnings and/or errors) and for which any finishing process was
        performed on this managed service or managed subunit."
    REFERENCE
        "See:   'finishing' and 'JmFinishingTC' in Job MIB (RFC 2707)."
    ::= { icMonitorEntry 9 }

icMonitorMemoryAllocErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total times that data stored by this managed service
        or managed subunit to local Imaging System memory
        caused a memory allocation failure."
    REFERENCE
        "See:   'hrStorageSize', 'hrStorageUsed', and
                'hrStorageAllocationFailures' in Host MIB (RFC 2790)."
    ::= { icMonitorEntry 10 }

icMonitorMemoryAllocWarnings OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total times that data stored by this managed service
        or managed subunit to local Imaging System memory
        exceeded an implementation-defined (or administratively
        configured) memory allocation threshold.

        Usage:  This counter is intended to support increasing the
        available memory on an Imaging System before job failures."
    REFERENCE
        "See:   'hrStorageSize', 'hrStorageUsed', and
                'hrStorageAllocationFailures' in Host MIB (RFC 2790)."
    ::= { icMonitorEntry 11 }

icMonitorStorageAllocErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total times that data stored by this managed service
        or managed subunit to a local or remote file system
        caused a storage allocation failure."
    REFERENCE
        "See:   'hrStorageSize', 'hrStorageUsed', and
                'hrStorageAllocationFailures' in Host MIB (RFC 2790)."
    ::= { icMonitorEntry 12 }

icMonitorStorageAllocWarnings OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total times that data stored by this managed service
        or managed subunit to a local or remote file system
        exceeded an implementation-defined (or administratively
        configured) storage allocation threshold.

        Usage:  This counter is intended to support increasing the
        available storage on an Imaging System before job failures."
    REFERENCE
        "See:   'hrStorageSize', 'hrStorageUsed', and
                'hrStorageAllocationFailures' in Host MIB (RFC 2790)."
    ::= { icMonitorEntry 13 }


--
--  Image Group (Conditionally Mandatory)
--

icImage                 OBJECT IDENTIFIER ::= { icMIBObjects 7 }

icImageTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcImageEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of work counters in images for managed services
        and/or managed subunits on this Imaging System."
    REFERENCE
        "See:   'icServiceTable' and 'icSubunitTable' in this MIB."
    ::= { icImage 1 }

icImageEntry OBJECT-TYPE
    SYNTAX      IcImageEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry of work counters in images for a managed service
        or a managed subunit on this Imaging System."
    INDEX     { icImageKeyIndex,
                icImageCycleType,
                icImageWorkType }
    ::= { icImageTable 1 }


IcImageEntry ::= SEQUENCE {
        --  image index elements
        icImageKeyIndex                 Integer32,
        icImageCycleType                IcCycleTypeTC,
        icImageWorkType                 IcWorkTypeTC,

        --  image counter elements
        icImageTotalImages              Counter32,
        icImageBlackImages              Counter32,
        icImageFullColorImages          Counter32
    }

icImageKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System."
    ::= { icImageEntry 1 }

icImageCycleType OBJECT-TYPE
    SYNTAX      IcCycleTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    ::= { icImageEntry 2 }

icImageWorkType OBJECT-TYPE
    SYNTAX      IcWorkTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of work for these counters."
    ::= { icImageEntry 3 }

icImageTotalImages OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "images"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total images input (e.g., 'icServiceType' of 'scan')
        or output (e.g., 'icServiceType' of 'faxOut') by
        this managed service or managed subunit."
    ::= { icImageEntry 4 }

icImageBlackImages OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "images"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Black images input (e.g., 'icServiceType' of 'scan')
        or output (e.g., 'icServiceType' of 'faxOut') by
        this managed service or managed subunit."
    ::= { icImageEntry 5 }

icImageFullColorImages OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "images"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Color images input (e.g., 'icServiceType' of 'scan')
        or output (e.g., 'icServiceType' of 'faxOut') by
        this managed service or managed subunit."
    ::= { icImageEntry 6 }


--
--  Impression Group (Conditionally Mandatory)
--

icImpression            OBJECT IDENTIFIER ::= { icMIBObjects 8 }

icImpressionTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcImpressionEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of work counters in impressions for managed services
        and/or managed subunits on this Imaging System."
    REFERENCE
        "See:   'icServiceTable' and 'icSubunitTable' in this MIB."
    ::= { icImpression 1 }

icImpressionEntry OBJECT-TYPE
    SYNTAX      IcImpressionEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry of work counters in impressions for a managed service
        or a managed subunit on this Imaging System."
    INDEX     { icImpKeyIndex,
                icImpCycleType,
                icImpWorkType }
    ::= { icImpressionTable 1 }


IcImpressionEntry ::= SEQUENCE {
        --  impression index elements
        icImpKeyIndex                   Integer32,
        icImpCycleType                  IcCycleTypeTC,
        icImpWorkType                   IcWorkTypeTC,

        --  impression counter elements
        icImpTotalImpressions           Counter32,
        icImpBlackImpressions           Counter32,
        icImpBlankImpressions           Counter32,
        icImpFullColorImpressions       Counter32,
        icImpHighlightColorImpressions  Counter32
    }

icImpKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System."
    ::= { icImpressionEntry 1 }

icImpCycleType OBJECT-TYPE
    SYNTAX      IcCycleTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    ::= { icImpressionEntry 2 }

icImpWorkType OBJECT-TYPE
    SYNTAX      IcWorkTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of work for these counters."
    ::= { icImpressionEntry 3 }

icImpTotalImpressions OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total hardcopy impressions printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    REFERENCE
        "See:   'jmJobImpressionsCompleted' in Job Mon MIB (RFC 2707);
                'job-impressions-completed' in IPP/1.1 (RFC 2911)."
    ::= { icImpressionEntry 4 }

icImpBlackImpressions OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Black hardcopy impressions printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icImpressionEntry 5 }

icImpBlankImpressions OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Blank hardcopy impressions printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icImpressionEntry 6 }

icImpFullColorImpressions OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Full color hardcopy impressions printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    REFERENCE
        "See:   'fullColorImpressionsCompleted' in Job Mon MIB
                (RFC 2707)."
    ::= { icImpressionEntry 7 }

icImpHighlightColorImpressions OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Highlight color hardcopy impressions printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    REFERENCE
        "See:   'highlightColorImpressionsCompleted' in Job Mon MIB
                (RFC 2707)."
    ::= { icImpressionEntry 8 }


--
--  Two Sided Group (Conditionally Mandatory)
--

icTwoSided              OBJECT IDENTIFIER ::= { icMIBObjects 9 }

icTwoSidedTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcTwoSidedEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of work counters in two-sided impressions for managed
        services and/or managed subunits on this Imaging System."
    REFERENCE
        "See:   'icServiceTable' and 'icSubunitTable' in this MIB."
    ::= { icTwoSided 1 }

icTwoSidedEntry OBJECT-TYPE
    SYNTAX      IcTwoSidedEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry of work counters in two-sided impressions for a
        managed service or managed subunit on this Imaging System."
    INDEX     { icTwoSidedKeyIndex,
                icTwoSidedCycleType,
                icTwoSidedWorkType }
    ::= { icTwoSidedTable 1 }


IcTwoSidedEntry ::= SEQUENCE {
        --  two-sided impression index elements
        icTwoSidedKeyIndex              Integer32,
        icTwoSidedCycleType             IcCycleTypeTC,
        icTwoSidedWorkType              IcWorkTypeTC,

        --  two-sided impression counter elements
        icTwoSidedTotalImps             Counter32,
        icTwoSidedBlackImps             Counter32,
        icTwoSidedBlankImps             Counter32,
        icTwoSidedFullColorImps         Counter32,
        icTwoSidedHighlightColorImps    Counter32
    }

icTwoSidedKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System."
    ::= { icTwoSidedEntry 1 }

icTwoSidedCycleType OBJECT-TYPE
    SYNTAX      IcCycleTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    ::= { icTwoSidedEntry 2 }

icTwoSidedWorkType OBJECT-TYPE
    SYNTAX      IcWorkTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of work for these counters."
    ::= { icTwoSidedEntry 3 }

icTwoSidedTotalImps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total hardcopy impressions printed two-sided by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    REFERENCE
        "See:   'jmJobImpressionsCompleted' in Job Mon MIB (RFC 2707);
                'job-impressions-completed' in IPP/1.1 (RFC 2911)."
    ::= { icTwoSidedEntry 4 }

icTwoSidedBlackImps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Black hardcopy impressions printed two-sided by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icTwoSidedEntry 5 }

icTwoSidedBlankImps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Blank hardcopy impressions printed two-sided by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icTwoSidedEntry 6 }

icTwoSidedFullColorImps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Full color hardcopy impressions printed two-sided by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    REFERENCE
        "See:   'fullColorImpressionsCompleted' in Job Mon MIB
                (RFC 2707)."
    ::= { icTwoSidedEntry 7 }

icTwoSidedHighlightColorImps OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "impressions"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Highlight color hardcopy impressions printed two-sided by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    REFERENCE
        "See:   'highlightColorImpressionsCompleted' in Job Mon MIB
                (RFC 2707)."
    ::= { icTwoSidedEntry 8 }


--
--  Sheet Group (Conditionally Mandatory)
--

icSheet                 OBJECT IDENTIFIER ::= { icMIBObjects 10 }

icSheetTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcSheetEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of work counters in sheets for managed services
        and/or managed subunits on this Imaging System."
    REFERENCE
        "See:   'icServiceTable' and 'icSubunitTable' in this MIB."
    ::= { icSheet 1 }

icSheetEntry OBJECT-TYPE
    SYNTAX      IcSheetEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry of work counters in sheets for a managed service
        or a managed subunit on this Imaging System."
    INDEX     { icSheetKeyIndex,
                icSheetCycleType,
                icSheetWorkType }
    ::= { icSheetTable 1 }


IcSheetEntry ::= SEQUENCE {
        --  sheet index elements
        icSheetKeyIndex                 Integer32,
        icSheetCycleType                IcCycleTypeTC,
        icSheetWorkType                 IcWorkTypeTC,

        --  sheet counter elements
        icSheetTotalSheets              Counter32,
        icSheetBlackSheets              Counter32,
        icSheetBlankSheets              Counter32,
        icSheetFullColorSheets          Counter32,
        icSheetHighlightColorSheets     Counter32
    }

icSheetKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System."
    ::= { icSheetEntry 1 }

icSheetCycleType OBJECT-TYPE
    SYNTAX      IcCycleTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    ::= { icSheetEntry 2 }

icSheetWorkType OBJECT-TYPE
    SYNTAX      IcWorkTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of work for these counters."
    ::= { icSheetEntry 3 }

icSheetTotalSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total media sheets printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    REFERENCE
        "See:   'sheetsCompleted' in Job Mon MIB (RFC 2707);
                'job-media-sheets-completed' in IPP/1.1 (RFC 2911)."
    ::= { icSheetEntry 4 }

icSheetBlackSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Black media sheets printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icSheetEntry 5 }

icSheetBlankSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Blank media sheets printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icSheetEntry 6 }

icSheetFullColorSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Full color media sheets printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icSheetEntry 7 }

icSheetHighlightColorSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Highlight color media sheets printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icSheetEntry 8 }


--
--  Traffic Group (Conditionally Mandatory)
--

icTraffic               OBJECT IDENTIFIER ::= { icMIBObjects 11 }

icTrafficTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcTrafficEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of work counters in K-octets for managed services
        and/or managed subunits on this Imaging System."
    REFERENCE
        "See:   'icServiceTable' and 'icSubunitTable' in this MIB."
    ::= { icTraffic 1 }

icTrafficEntry OBJECT-TYPE
    SYNTAX      IcTrafficEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of work counters in K-octets for a managed service
        or a managed subunit on this Imaging System."
    INDEX     { icTrafficKeyIndex,
                icTrafficCycleType,
                icTrafficWorkType }
    ::= { icTrafficTable 1 }


IcTrafficEntry ::= SEQUENCE {
        --  traffic index elements
        icTrafficKeyIndex               Integer32,
        icTrafficCycleType              IcCycleTypeTC,
        icTrafficWorkType               IcWorkTypeTC,

        --  traffic counter elements
        icTrafficLocalStorageKOctets    Counter32,
        icTrafficRemoteStorageKOctets   Counter32,
        icTrafficJobInputKOctets        Counter32,
        icTrafficJobOutputKOctets       Counter32,
        icTrafficJobInputMessages       Counter32,
        icTrafficJobOutputMessages      Counter32
    }

icTrafficKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System."
    ::= { icTrafficEntry 1 }

icTrafficCycleType OBJECT-TYPE
    SYNTAX      IcCycleTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    ::= { icTrafficEntry 2 }

icTrafficWorkType OBJECT-TYPE
    SYNTAX      IcWorkTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of work for these counters."
    ::= { icTrafficEntry 3 }

icTrafficLocalStorageKOctets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "koctets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total amount of data stored by this managed service
        or managed subunit to the local file system of this
        Imaging System."
    REFERENCE
        "See:   'hrStorageSize' and 'hrStorageUsed' in
                Host Resources MIB (RFC 2790)."
    ::= { icTrafficEntry 4 }

icTrafficRemoteStorageKOctets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "koctets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total amount of data stored by this managed service
        or managed subunit to a remote file system from this
        Imaging System."
    REFERENCE
        "See:   'hrStorageSize' and 'hrStorageUsed' in
                Host Resources MIB (RFC 2790)."
    ::= { icTrafficEntry 5 }

icTrafficJobInputKOctets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "koctets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total amount of data received on ALL supported job channels
        by this managed service (e.g., 'icServiceType' of 'faxIn')
        or managed subunit."
    REFERENCE
        "See:   'prtChannelTable' in Printer MIB v1 (RFC 1759) and
                Printer MIB v2 (RFC 3805);
                'ifInOctets' in MIB-II (RFC 1213)."
    ::= { icTrafficEntry 6 }

icTrafficJobOutputKOctets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "koctets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total amount of data sent on ALL supported job channels
        by this managed service (e.g., 'icServiceType' of 'faxOut')
        or managed subunit."
    REFERENCE
        "See:   'ifOutOctets' in MIB-II (RFC 1213)."
    ::= { icTrafficEntry 7 }

icTrafficJobInputMessages OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "messages"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total messages received on ALL supported job channels
        by this managed service (e.g., 'icServiceType' of 'emailIn')
        or managed subunit."
    REFERENCE
        "See:   'prtChannelTable' in Printer MIB v1 (RFC 1759) and
                Printer MIB v2 (RFC 3805);
                'ifInUcastPkts' in MIB-II (RFC 1213)."
    ::= { icTrafficEntry 8 }

icTrafficJobOutputMessages OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "messages"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total messages sent on ALL supported job channels
        by this managed service (e.g., 'icServiceType' of 'emailOut')
        or managed subunit."
    REFERENCE
        "See:   'ifOutUcastPkts' in MIB-II (RFC 1213)."
    ::= { icTrafficEntry 9 }


--
--  Media Used Group (Optional)
--

icMediaUsed             OBJECT IDENTIFIER ::= { icMIBObjects 12 }

icMediaUsedTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IcMediaUsedEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of counters for each specific media actually consumed
        by managed services and/or managed subunits configured
        on this Imaging System."
    ::= { icMediaUsed 1 }

icMediaUsedEntry OBJECT-TYPE
    SYNTAX      IcMediaUsedEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry of counters for one specific media actually consumed
        by a managed service or a managed subunit configured
        on this Imaging System."
    INDEX     { icMediaUsedKeyIndex,
                icMediaUsedCycleType,
                icMediaUsedIndex }
    ::= { icMediaUsedTable 1 }


IcMediaUsedEntry ::= SEQUENCE {
        --  media used index elements
        icMediaUsedKeyIndex             Integer32,
        icMediaUsedCycleType            IcCycleTypeTC,
        icMediaUsedIndex                Integer32,

        --  media used counter elements
        icMediaUsedTotalSheets          Counter32,
        icMediaUsedBlackSheets          Counter32,
        icMediaUsedBlankSheets          Counter32,
        icMediaUsedFullColorSheets      Counter32,
        icMediaUsedHighlightColorSheets Counter32,

        --  media used description elements
        icMediaUsedInfo                 SnmpAdminString,
        icMediaUsedName                 SnmpAdminString,
        icMediaUsedSizeName             SnmpAdminString
    }

icMediaUsedKeyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Local key of this managed service (value of 'icServiceKey')
        or managed subunit (value of 'icSubunitKey') on this
        Imaging System."
    ::= { icMediaUsedEntry 1 }

icMediaUsedCycleType OBJECT-TYPE
    SYNTAX      IcCycleTypeTC
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The type of cycle for these counters."
    ::= { icMediaUsedEntry 2 }

icMediaUsedIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The instance of this specific media size."
    REFERENCE
        "See:   'icMediaUsedSizeName' and 'icMediaUsedInfo'."
    ::= { icMediaUsedEntry 3 }

icMediaUsedTotalSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total sheets of this specific media printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    REFERENCE
        "See:   'sheetsCompleted' in Job Mon MIB (RFC 2707);
                'job-media-sheets-completed' in IPP/1.1 (RFC 2911)."
    ::= { icMediaUsedEntry 4 }

icMediaUsedBlackSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Black sheets of this specific media printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icMediaUsedEntry 5 }

icMediaUsedBlankSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Blank sheets of this specific media printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icMediaUsedEntry 6 }

icMediaUsedFullColorSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Full color sheets of this specific media printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icMediaUsedEntry 7 }

icMediaUsedHighlightColorSheets OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "sheets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Highlight color sheets of this specific media printed by this
        managed service (e.g., 'icServiceType' of 'print')
        or managed subunit (e.g., 'icSubunitType' of 'marker')."
    ::= { icMediaUsedEntry 8 }

icMediaUsedInfo OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE(0..255))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The description of this specific media,
        for use with remote network management scripts and GUIs.

        For example:    'Light blue deckle-edge letter stock'.

        Usage:  This description MUST clearly distinguish different
        instances of the same media size in 'icMediaUsedTable' (for
        example, by including specific media color, weight, etc.)."
    REFERENCE
        "See:   'icMediaUsedSizeName' and 'icMediaUsedIndex'."
    ::= { icMediaUsedEntry 9 }

icMediaUsedName OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE(0..63))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The friendly locally unique name for this specific media,
        for use with remote network management scripts and GUIs.

        For example:    'customer-reply' or 'na-letter-colored'."
    REFERENCE
        "See:   'Appendix C: 'media' keyword values' and
                section 4.2.11 'media' in IPP/1.1 (RFC2911);
                'mediumRequested' and 'mediumConsumed' in Job Mon MIB
                (RFC 2707)."
    ::= { icMediaUsedEntry 10 }

icMediaUsedSizeName OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE(0..63))
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The media size self-describing name for this specific media,
        for use with remote network management scripts and GUIs.

        For example:    'na_letter_8.5x11in'."
    REFERENCE
        "See:   PWG Media Standardized Names' (IEEE/ISTO PWG 5101.1);
                'icMediaUsedIndex' and 'icMediaUsedInfo'."
    ::= { icMediaUsedEntry 11 }


--
--  Conformance Statements
--

icMIBCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statements for Imaging Systems that implement
        the PWG Imaging Counter MIB."
    MODULE  -- this module
    MANDATORY-GROUPS { icGeneralGroup,
                       icKeyGroup,
                       icServiceGroup,
                       icTimeGroup,
                       icMonitorGroup }

    GROUP   icSubunitGroup
    DESCRIPTION
        "Conditionally Mandatory - subunit object group."

    GROUP   icImageGroup
    DESCRIPTION
        "Conditionally Mandatory - image counter object group."

    GROUP   icImpressionGroup
    DESCRIPTION
        "Conditionally Mandatory - impression counter object group."

    GROUP   icTwoSidedGroup
    DESCRIPTION
        "Conditionally Mandatory - two-sided counter object group."

    GROUP   icSheetGroup
    DESCRIPTION
        "Conditionally Mandatory - sheet counter object group."

    GROUP   icTrafficGroup
    DESCRIPTION
        "Conditionally Mandatory - traffic counter object group."

    GROUP   icMediaUsedGroup
    DESCRIPTION
        "Optional - media used counter object group."

    ::= { icMIBConformance 1 }


--
--  Conformance Groups
--

icGeneralGroup OBJECT-GROUP
    OBJECTS {
        icGeneralNaturalLanguage,
        icGeneralTotalServiceRecords,
        icGeneralTotalSubunitRecords,
        icGeneralTotalMediaUsedRecords
    }
    STATUS      current
    DESCRIPTION
        "Mandatory - general object group.

        An Imaging System MUST support and implement this object group."
    ::= { icMIBObjectGroups 1 }

icKeyGroup OBJECT-GROUP
    OBJECTS {
        icKeyServiceType,
        icKeyServiceIndex,
        icKeySubunitType,
        icKeySubunitIndex
    }
    STATUS      current
    DESCRIPTION
        "Mandatory - key object group.

        An Imaging System MUST support and implement this object group
        for 'icKeyServiceType' of 'system' (overall counters).

        An Imaging System MAY support and implement this object group
        for individual managed services and/or managed subunits."
    ::= { icMIBObjectGroups 2 }

icServiceGroup OBJECT-GROUP
    OBJECTS {
        icServiceKey,
        icServiceInfo,
        icServiceJobSetIndex
    }
    STATUS      current
    DESCRIPTION
        "Mandatory - service object group.

        An Imaging System MUST support and implement this object group
        for 'icServiceType' of 'system' (overall counters).

        An Imaging System MAY support and implement this object group
        for individual managed services."
    ::= { icMIBObjectGroups 3 }

icSubunitGroup OBJECT-GROUP
    OBJECTS {
        icSubunitKey,
        icSubunitInfo
    }
    STATUS      current
    DESCRIPTION
        "Conditionally Mandatory - subunit object group.

        An Imaging System MUST support and implement this object group,
        if the Imaging System supports any managed subunit,
        for example, 'icSubunitType' of 'channel' for 'prtChannelTable'
        in Printer MIB v1 (RFC 1759) or Printer MIB v2 (RFC 3805)."
    ::= { icMIBObjectGroups 4 }

icTimeGroup OBJECT-GROUP
    OBJECTS {
        icTimeTotalSeconds,
        icTimeDownSeconds,
        icTimeMaintenanceSeconds,
        icTimeProcessingSeconds
    }
    STATUS      current
    DESCRIPTION
        "Mandatory - time counter object group.

        An Imaging System MUST support and implement this object group
        for 'icServiceType' of 'system' (overall counters).

        An Imaging System MAY support and implement this object group
        for individual managed services and/or managed subunits."
    ::= { icMIBObjectGroups 5 }

icMonitorGroup OBJECT-GROUP
    OBJECTS {
        icMonitorConfigChanges,
        icMonitorTotalAlerts,
        icMonitorCriticalAlerts,
        icMonitorAbortedJobs,
        icMonitorCanceledJobs,
        icMonitorCompletedJobs,
        icMonitorCompletedFinisherJobs,
        icMonitorMemoryAllocErrors,
        icMonitorMemoryAllocWarnings,
        icMonitorStorageAllocErrors,
        icMonitorStorageAllocWarnings
    }
    STATUS      current
    DESCRIPTION
        "Mandatory - monitor counter object group.

        An Imaging System MUST support and implement this object group
        for 'icServiceType' of 'system' (overall counters).

        An Imaging System MAY support and implement this object group
        for individual managed services and/or managed subunits."
    ::= { icMIBObjectGroups 6 }

icImageGroup OBJECT-GROUP
    OBJECTS {
        icImageTotalImages,
        icImageBlackImages,
        icImageFullColorImages
    }
    STATUS      current
    DESCRIPTION
        "Conditionally Mandatory - image counter object group.

        An Imaging System MUST support and implement this object group,
        if the Imaging System supports any managed service with
        'icServiceType' of 'copy', 'scan', 'faxIn/Out', or
        'networkFaxIn/Out'."
    ::= { icMIBObjectGroups 7 }

icImpressionGroup OBJECT-GROUP
    OBJECTS {
        icImpTotalImpressions,
        icImpBlackImpressions,
        icImpBlankImpressions,
        icImpFullColorImpressions,
        icImpHighlightColorImpressions
    }
    STATUS      current
    DESCRIPTION
        "Conditionally Mandatory - impression counter object group.

        An Imaging System MUST support and implement this object group,
        if the Imaging System supports any managed service with
        'icServiceType' of 'copy' or 'print'."
    ::= { icMIBObjectGroups 8 }

icTwoSidedGroup OBJECT-GROUP
    OBJECTS {
        icTwoSidedTotalImps,
        icTwoSidedBlackImps,
        icTwoSidedBlankImps,
        icTwoSidedFullColorImps,
        icTwoSidedHighlightColorImps
    }
    STATUS      current
    DESCRIPTION
        "Conditionally Mandatory - two-sided counter object group.

        An Imaging System MUST support and implement this object group,
        if the Imaging System supports any managed service with
        'icServiceType' of 'copy' or 'print' that supports two-sided
        printing."
    ::= { icMIBObjectGroups 9 }

icSheetGroup OBJECT-GROUP
    OBJECTS {
        icSheetTotalSheets,
        icSheetBlackSheets,
        icSheetBlankSheets,
        icSheetFullColorSheets,
        icSheetHighlightColorSheets
    }
    STATUS      current
    DESCRIPTION
        "Conditionally Mandatory - sheet counter object group.

        An Imaging System MUST support and implement this object group,
        if the Imaging System supports any managed service with
        'icServiceType' of 'copy' or 'print'."
    ::= { icMIBObjectGroups 10 }

icTrafficGroup OBJECT-GROUP
    OBJECTS {
        icTrafficLocalStorageKOctets,
        icTrafficRemoteStorageKOctets,
        icTrafficJobInputKOctets,
        icTrafficJobOutputKOctets,
        icTrafficJobInputMessages,
        icTrafficJobOutputMessages
    }
    STATUS      current
    DESCRIPTION
        "Conditionally Mandatory - traffic counter object group.

        An Imaging System MUST support and implement this object group,
        if the Imaging System supports any managed service with
        'icServiceType' of 'emailIn/Out', 'faxIn/Out', or
        'networkFaxIn/Out'."
    ::= { icMIBObjectGroups 11 }

icMediaUsedGroup OBJECT-GROUP
    OBJECTS {
        icMediaUsedTotalSheets,
        icMediaUsedBlackSheets,
        icMediaUsedBlankSheets,
        icMediaUsedFullColorSheets,
        icMediaUsedHighlightColorSheets,
        icMediaUsedName,
        icMediaUsedInfo
    }
    STATUS      current
    DESCRIPTION
        "Optional - media used counter object group.

        An Imaging System MAY support and implement this object group."
    ::= { icMIBObjectGroups 12 }

END